Reduction of backreflection noise in resonator micro-optic gyro by integer period sampling
In resonator micro-optic gyros (RMOGs), the interference between the backreflection light beam of one pathway and the signal light beam of the other pathway deteriorates the gyro output waveforms, resulting in severe reduction in the gyro's accuracy. In this paper, an integer period sampling (I...
Gespeichert in:
Veröffentlicht in: | Applied optics (2004) 2013-11, Vol.52 (32), p.7712-7717 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In resonator micro-optic gyros (RMOGs), the interference between the backreflection light beam of one pathway and the signal light beam of the other pathway deteriorates the gyro output waveforms, resulting in severe reduction in the gyro's accuracy. In this paper, an integer period sampling (IPS) method is introduced to minimize the sampling error caused by backreflection in RMOG for the first time to our knowledge. The experimental results show that both the bias repeatability and the short-term bias stability become better when the IPS condition is satisfied. A bias stability of 0.41°/s over one hour with an integration time of 10 s has been realized in a RMOG that employs a silica waveguide ring resonator. |
---|---|
ISSN: | 1559-128X 2155-3165 1539-4522 |
DOI: | 10.1364/AO.52.007712 |