Reduction of backreflection noise in resonator micro-optic gyro by integer period sampling

In resonator micro-optic gyros (RMOGs), the interference between the backreflection light beam of one pathway and the signal light beam of the other pathway deteriorates the gyro output waveforms, resulting in severe reduction in the gyro's accuracy. In this paper, an integer period sampling (I...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied optics (2004) 2013-11, Vol.52 (32), p.7712-7717
Hauptverfasser: Wang, Junjie, Feng, Lishuang, Zhi, Yinzhou, Liu, Huilan, Wang, Wei, Lei, Ming
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In resonator micro-optic gyros (RMOGs), the interference between the backreflection light beam of one pathway and the signal light beam of the other pathway deteriorates the gyro output waveforms, resulting in severe reduction in the gyro's accuracy. In this paper, an integer period sampling (IPS) method is introduced to minimize the sampling error caused by backreflection in RMOG for the first time to our knowledge. The experimental results show that both the bias repeatability and the short-term bias stability become better when the IPS condition is satisfied. A bias stability of 0.41°/s over one hour with an integration time of 10 s has been realized in a RMOG that employs a silica waveguide ring resonator.
ISSN:1559-128X
2155-3165
1539-4522
DOI:10.1364/AO.52.007712