Validity and reliability of 3D marker based scapular motion analysis: A systematic review

Abstract Methods based on cutaneous markers are the most popular for the recording of three dimensional scapular motion analysis. Numerous methods have been evaluated, each showing different levels of accuracy and reliability. The aim of this review was to report the metrological properties of 3D sc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomechanics 2014-07, Vol.47 (10), p.2219-2230
Hauptverfasser: Lempereur, Mathieu, Brochard, Sylvain, Leboeuf, Fabien, Rémy-Néris, Olivier
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Methods based on cutaneous markers are the most popular for the recording of three dimensional scapular motion analysis. Numerous methods have been evaluated, each showing different levels of accuracy and reliability. The aim of this review was to report the metrological properties of 3D scapular kinematic measurements using cutaneous markers and to make recommendations based on metrological evidence. A database search was conducted using relevant keywords and inclusion/exclusion criteria in 5 databases. 19 articles were included and assessed using a quality score. Concurrent validity and reliability were analyzed for each method. Six different methods are reported in the literature, each based on different marker locations and post collection computations. The acromion marker cluster (AMC) method coupled with a calibration of the scapula with the arm at rest is the most studied method. Below 90–100° of humeral elevation, this method is accurate to about 5° during arm flexion and 7° during arm abduction compared to palpation (average of the 3 scapular rotation errors). Good to excellent within-session reliability and moderate to excellent between-session reliability have been reported. The AMC method can be improved using different or multiple calibrations. Other methods using different marker locations or more markers on the scapula blade have been described but are less accurate than AMC methods. Based on current metrological evidence we would recommend (1) the use of an AMC located at the junction of the scapular spine and the acromion, (2) the use of a single calibration at rest if the task does not reach 90° of humeral elevation, (3) the use of a second calibration (at 90° or 120° of humeral elevation), or multiple calibrations above 90° of humeral elevation.
ISSN:0021-9290
1873-2380