Parasitological Profile of Raw Wastewater and the Efficacy of Biosand Filter in Reduction of Parasite Ova and Cysts
The disposal of wastewater in water bodies has a negative impact in the environment and the health of people who use such water bodies for either irrigation or drinking purposes. In this study, we evaluated the parasitological profile of wastewater from the Ahmadu Bello University Teaching Hospital...
Gespeichert in:
Veröffentlicht in: | Journal of Applied Sciences and Environmental Management 2014-03, Vol.18 (1), p.5-5 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The disposal of wastewater in water bodies has a negative impact in the
environment and the health of people who use such water bodies for
either irrigation or drinking purposes. In this study, we evaluated the
parasitological profile of wastewater from the Ahmadu Bello University
Teaching Hospital sewage treatment plant, Zaria, Nigeria using the
magnesium sulphate floatation method. The parasite removal efficiency
of biosand filter was also tested in comparison with the sewage
treatment plant. A total of 960 L of wastewater was examined and a
significant level of parasite eggs, cysts and oocysts were detected. In
all, 1,648 parasites eggs, cysts and oocysts per litre were counted.
Ova of Ascaris spp showed the highest count/litre of 307 (18.63%)
followed by ova of Taenia spp (n=287; 17.42%). The least count per
litre was exhibited by cysts of Giardia spp (n=58; 3.52%). The
analysis revealed that 52.61% of the parasite eggs, cysts and oocysts
was removed by the sewage treatment plant while egg removal efficiency
of the biosand filter was 97.45%. Further comparison of mean parasite
eggs/litre in the effluents of biosand filter and the sewage treatment
plant using Wilcoxon's Signed Ranks Test indicated a significant
difference (p < 0.05) with biosand filter having lower counts per
litre. The results obtained therefore demonstrate that the raw
wastewater was laden with parasite eggs, cysts and oocysts and hence
pose public health threat to the users of the effluent downstream. The
biosand filter was more efficient than the sewage treatment plant; its
effluent contains insufficient level of the ova, cysts and oocysts of
parasites well below the less than one ( |
---|---|
ISSN: | 1119-8362 2659-1502 1119-8362 2659-1499 |
DOI: | 10.4314/jasem.v18i1.1 |