Predicting falls using two instruments (the Hendrich Fall Risk Model and the Morse Fall Scale) in an acute care setting in Lebanon

Aims and objectives To assess the predictive value of two instruments (the Morse Fall Scale (MFS) and the Heindrich II Fall Risk Model (HFRM)] in a Middle Eastern country (Lebanon) and to evaluate the factors that are related to falls. Design A prospective observational cross‐sectional design was us...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical nursing 2014-06, Vol.23 (11-12), p.1620-1629
Hauptverfasser: Nassar, Nada, Helou, Nancy, Madi, Chantal
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Aims and objectives To assess the predictive value of two instruments (the Morse Fall Scale (MFS) and the Heindrich II Fall Risk Model (HFRM)] in a Middle Eastern country (Lebanon) and to evaluate the factors that are related to falls. Design A prospective observational cross‐sectional design was used. Background Falls and fall‐related injuries in the acute care settings contribute a substantial health and economic burden on patients and organisations. Preventing falls is a priority for most healthcare organisations. While the risk of falling cannot be eliminated, it can be significantly reduced through accurate assessment of patients' risk of falling. Methods Data from 1815 inpatients at the American University of Beirut Medical Center (AUBMC) in Lebanon were evaluated using two instruments to predict falls: the MFS and the HFRM. Results The incidence of falls was 2·7% in one year. The results indicate that while the instruments were significantly correlated, the HFRM was more sensitive in predicting falls than the MFS. The internal consistency of both scales was moderate, but inter‐rater reliability was high. Patients using antiepileptic drugs and assistance devises had higher odds of falling. Conclusions Although both instruments were easy to use in a Middle Eastern country, the HFRM rather than the MFS is recommended for inpatients in an acute care setting as it had higher sensitivity and specificity. Relevance to clinical practice It is recommended that while the HFRM had adequate sensitivity, it is not seamless, and as such, nurses should not rely entirely on it. Rather, nurses should use their expert clinical judgement, their ethical obligations and cultural considerations to implement a safer environment of care for the patient.
ISSN:0962-1067
1365-2702