Development of Noise Measurements. Part 7. Coriolis Mass Flowmeter and its Errors

Coriolis mass flowmeter instrumental and dynamic errors are studied. They can be decreased by the thermocouple usage of R or S types instead of Pt100 sensors. The dynamic error analysis shows that it is able to improve the operation accuracy in the dynamic regime and eliminate the initial period of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors & transducers 2013-11, Vol.158 (11), p.249-249
Hauptverfasser: Skoropad, Pylyp, Stadnyk, Bohdan, Yatsyshyn, Svyatoslav, Pol'ova, Halyna
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Coriolis mass flowmeter instrumental and dynamic errors are studied. They can be decreased by the thermocouple usage of R or S types instead of Pt100 sensors. The dynamic error analysis shows that it is able to improve the operation accuracy in the dynamic regime and eliminate the initial period of the flowmeter exploitation in the error compensation absence regime. In consequence of the instrumental error consideration, the expediency of the differential thermocouples installation with the reduced performance dispersion lowered by taking into account of local and extensive inhomogeneities as result of technological deviations of wire production.