FIRE PERFORMANCE OF MIXED STRUCTURES COMPOSED OF REINFORCED CONCRETE COLUMNS AND STEEL BEAMS

Mixed structures composed of reinforced concrete columns and steel beams can realize larger building spaces, whereas reinforced concrete columns are subjected to thermal stresses due to thermal elongation of long span steel beams in case of fire. It is very important to clarify the load carrying cap...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nihon Kenchiku Gakkai kōzōkei ronbunshū 2013-01, Vol.77 (679), p.1463-1471
Hauptverfasser: MATSUDO, Masashi, SATOH, Yukihiro, SASAKI, Hitoshi, HIRASHIMA, Takeo, IGUCHI, Shingo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Mixed structures composed of reinforced concrete columns and steel beams can realize larger building spaces, whereas reinforced concrete columns are subjected to thermal stresses due to thermal elongation of long span steel beams in case of fire. It is very important to clarify the load carrying capacity of the complicated beam-column connections in fire. This paper presents the results of the sub-frame fire tests of a mixed structure composed of up-and-down RC column, steel beam and the connection. The test results indicate the non-fire-protected connection covered with thin steel plate has load carrying capacity during 3 hours of standard fire temperature curve. In this paper, fire performance of the beam-column connections is discussed.
ISSN:1340-4202
1881-8153