RESEARCH ON ASBESTOS CONTAINING THERMAL INSULATION MATERIALS FOR CHIMNEY PIPES ABOUT DEGREE OF DETERIORATION AND ASBESTOS FIBER RELEASE INDOORS FROM THOSE MATERIALS

Thermal insulation materials for chimney pipes are concerned to deteriorate by freezing and thawing effect especially in cold areas. In this research, airborne fibrous particles concentration was measured at indoor, inside of chimney pipes and outdoor around buildings which use asbestos containing t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Structural and Construction Engineering (Transactions of AIJ) 2013/04/30, Vol.78(686), pp.665-670
Hauptverfasser: KOGA, Junko, KAWAGUCHI, Masato, WAKUI, Takeshi, OYAMA, Yoshie, KOMATSU, Tamotsu, TOYOGUCHI, Toshiyuki, MOTOHASHI, Kenji, KAMATA, Motoyasu
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Thermal insulation materials for chimney pipes are concerned to deteriorate by freezing and thawing effect especially in cold areas. In this research, airborne fibrous particles concentration was measured at indoor, inside of chimney pipes and outdoor around buildings which use asbestos containing thermal insulation materials for chimney pipes, and degree of deterioration of those materials was verified. As a result, asbestos fibers were detected indoors of 2 buildings, inside of chimney pipes of 5 buildings and various degree of deterioration of thermal insulation materials for chimney pipes were examined.