A novel coronary active perfusion system using a conventional intra-aortic balloon pump for off-pump coronary artery bypass grafting

Objective It is important for coronary active perfusion systems to avoid myocardial ischemia during off-pump coronary artery bypass grafting. We have developed a new concept for a perfusion system to pump blood based on changes in helium gas volume. This system uses a conventional intra-aortic ballo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of thoracic and cardiovascular surgery 2014-07, Vol.148 (1), p.304-310
Hauptverfasser: Kiuchi, Ryuta, MD, Tomita, Shigeyuki, MD, Yamaguchi, Shojiro, MD, Nishida, Yuji, MD, Ohtake, Hiroshi, MD, Nakamura, Hiroyuki, MD, Watanabe, Go, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective It is important for coronary active perfusion systems to avoid myocardial ischemia during off-pump coronary artery bypass grafting. We have developed a new concept for a perfusion system to pump blood based on changes in helium gas volume. This system uses a conventional intra-aortic balloon pump to activate the perfusion pump. Our study used basic and animal experiments to investigate the most suitable system for coronary perfusion using this new concept. Methods A conventional intra-aortic balloon pump was used to supply power. A device for perfusion was developed with a balloon placed inside a stiff syringe barrel. The device was connected to the helium gas line of the intra-aortic balloon pump. Changes in flow with changes in augmentation level were noted when volumes outside and within the balloon were changed. Six pigs with occlusion of the left anterior descending artery were used for system validation, with monitoring to identify changes in hemodynamics and cardiac enzyme levels. Results In the basic experiment, an 80-mL outside volume and 3.0-mL inner volume resulted in the greatest percentage change in flow rate with respect to changes in augmentation. In the animal experiment, the new coronary active perfusion system prevented myocardial ischemia during coronary occlusion. Conclusions We clarified the most suitable method for our new coronary active perfusion system. Using this system, safe anastomosis was consistently performed in animal experiments. Clinically, off-pump coronary artery bypass may potentially be performed more safely and easily using this new system.
ISSN:0022-5223
1097-685X
DOI:10.1016/j.jtcvs.2013.11.049