Usefulness of Top-hat Transform Processing in Whole Body Bone Scintigraphy

To assess the usefulness of top-hat transform processing in whole body bone scintigraphy, five radiological technicians interpreted both original and top-hat processed images to determine the improvement of lesion detectability and interpretation time. For the evaluation of detectability, receiver o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Japanese Journal of Radiological Technology 2013/01/20, Vol.69(1), pp.41-48
Hauptverfasser: Kita, Akinobu, Sugimoto, Katsuya, Tsuchida, Tatsurou, Kishimoto, Takahiro, Toi, Akiko, Shimada, Masato, Adachi, Toshiki
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To assess the usefulness of top-hat transform processing in whole body bone scintigraphy, five radiological technicians interpreted both original and top-hat processed images to determine the improvement of lesion detectability and interpretation time. For the evaluation of detectability, receiver operating characteristic (ROC) analysis was performed. The area under the curve (AUC) calculated from the ROC curve was improved in all observers (from 0.786 to 0.864 in average), although no significant difference was observed. However, the interpretation time was improved significantly (from 24.5 to 16.2 s in average). Top-hat transform processing in whole body bone scintigraphy is thought to be useful for the improvement of lesion detectability and interpretation time.
ISSN:0369-4305
1881-4883
DOI:10.6009/jjrt.2013_JSRT_69.1.41