Development of a 32-detector CdTe matrix for the SVOM ECLAIRs X/Gamma camera: Preliminary results

ECLAIRs, a 2D coded-mask imaging telescope on the Sino-French SVOM space mission, will detect and locate gamma-ray bursts (GRBs) between 4 and 150keV. The detector array is an assembly of 6400 Schottky CdTe detectors of size 4×4×1mm3, biased from −100V to −600V and operated at −20°C to minimize the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2013-12, Vol.732, p.122-125
Hauptverfasser: Lacombe, K., Nasser, G., Amoros, C., Atteia, J.-L., Barret, D., Billot, M., Cordier, B., Gevin, O., Godet, O., Gonzalez, F., Houret, B., Landé, J., Lugiez, F., Mandrou, P., Martin, J.-A., Marty, W., Mercier, K., Pons, R., Rambaud, D., Ramon, P., Rouaix, G., Waegebaert, V.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:ECLAIRs, a 2D coded-mask imaging telescope on the Sino-French SVOM space mission, will detect and locate gamma-ray bursts (GRBs) between 4 and 150keV. The detector array is an assembly of 6400 Schottky CdTe detectors of size 4×4×1mm3, biased from −100V to −600V and operated at −20°C to minimize the leakage current and maximize the polarization time. The remarkable low-energy threshold is achieved through various steps: an extensive detectors selection, a low-noise 32 channels ASIC study, and the design of an innovative detection module called XRDPIX formed by a thick film ceramic holding 32 detectors, a high voltage grid and an HTCC substrate housing the ASIC within a hermetic cavity. In this paper, we describe the XRDPIX module and explain the results of first tests to measure the linearity and compare the sources of noise, such as leakage currents and the Equivalent Noise Charge (ENC) measured on ASIC Ceramics. We confront these values with the energy threshold and spectral resolution made with dedicated test benches. Finally, we present the superposition of 32 calibrated spectra of one XRDPIX module, showing the excellent homogeneity of the 32 detectors and the achievement of a detection threshold at 4keV over the entire module. •We develop X and gamma rays detection modules to shape a space telescope.•The main goal of 4keV threshold is reached thanks to a new hybrid based on CdTe.•Great spectral performance depends on low equivalent noise charge of ASIC on ceramics.•We study the good linearity of the calibration curve below the 16keV energy.•An outgassing stage will decrease the leakage current of detectors glued on ceramics.
ISSN:0168-9002
1872-9576
DOI:10.1016/j.nima.2013.07.003