Half-lives of 221Fr, 217At, 213Bi, 213Po and 209Pb from the 225Ac decay series
The half-lives of 221Fr, 217At, 213Bi, 213Po, and 209Pb were measured by means of an ion-implanted planar Si detector for alpha and beta particles emitted from weak 225Ac sources or from recoil sources, which were placed in a quasi-2π counting geometry. Recoil sources were prepared by collecting ato...
Gespeichert in:
Veröffentlicht in: | Applied radiation and isotopes 2013-07, Vol.77, p.32-37 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The half-lives of 221Fr, 217At, 213Bi, 213Po, and 209Pb were measured by means of an ion-implanted planar Si detector for alpha and beta particles emitted from weak 225Ac sources or from recoil sources, which were placed in a quasi-2π counting geometry. Recoil sources were prepared by collecting atoms from an open 225Ac source onto a glass substrate. The 221Fr and 213Bi half-lives were determined by following the alpha particle emission rate of recoil sources as a function of time. Similarly, the 209Pb half-life was determined from the beta particle count rate. The shorter half-lives of 217At and 213Po were deduced from delayed coincidence measurements on weak 225Ac sources using digital data acquisition in list mode. The resulting values: T1/2(221Fr)=4.806 (6) min, T1/2(217At)=32.8 (3)ms, T1/2(213Bi)=45.62 (6)min, T1/2(213Po)=3.708 (8)μs, and T1/2(209Pb)=3.232 (5)h were in agreement only with the best literature data.
► The decay series of 225Ac–213Bi is important for use in alpha-immunotherapy. ► The half-lives of 221Fr, 217At, 213Bi, 213Po, and 209Pb were measured. ► Used ion-implanted planar Si detector and digital data acquisition in list mode. ► The results agree with the best literature data only. |
---|---|
ISSN: | 0969-8043 1872-9800 |