Novel method for sludge blanket measurements

The most widely used methods for sludge blanket measurements are based on acoustic or optic principles. In operation, both methods are expensive and often maintenance-intensive. Therefore a novel, reliable and simple method for sludge blanket measurement is proposed. It is based on the differential...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Water science and technology 2014-01, Vol.69 (4), p.775-782
Hauptverfasser: SCHEWERDA, J, FÖRSTER, G, HEINRICHMEIER, J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The most widely used methods for sludge blanket measurements are based on acoustic or optic principles. In operation, both methods are expensive and often maintenance-intensive. Therefore a novel, reliable and simple method for sludge blanket measurement is proposed. It is based on the differential pressure measurement in the sludge zone compared with the differential pressure in the clear water zone, so that it is possible to measure the upper and the lower sludge level in a tank. Full-scale tests of this method were done in the secondary clarifier at the waste water treatment plant in Hecklingen, Germany. The result shows a good approximation of the manually measured sludge level.
ISSN:0273-1223
1996-9732
DOI:10.2166/wst.2013.775