Experimental and analytical study of a loop heat pipe at a positive elevation using neutron radiography
An experimental and analytical study has been conducted of a loop heat pipe's steady state operating conditions at a positive elevation, which refers to when the condenser is higher than the evaporator. A unique trend of the steady state operating temperature as a function of evaporator heat lo...
Gespeichert in:
Veröffentlicht in: | International journal of thermal sciences 2014-03, Vol.77 (77), p.84-95 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An experimental and analytical study has been conducted of a loop heat pipe's steady state operating conditions at a positive elevation, which refers to when the condenser is higher than the evaporator. A unique trend of the steady state operating temperature as a function of evaporator heat load at a positive elevation was observed in the experimental data. A gravity-assisted operating theory was proposed and explained in detail. In addition, the proposed hypothesis was validated by neutron radiography, a non-destructive visualization tool. When the LHP is operated at a positive elevation, it can operate in the capillary-controlled mode, which means the system is driven by pressure gain from both surface tension and liquid head, or in the gravity-controlled mode, which means the system is driven only by the pressure gain from the liquid head. A pressure–temperature diagram illustrating the thermodynamic states of the circulating fluid was presented when the system is operating in a gravity-controlled mode. Experimental temperature data were presented for a loop heat pipe operating at 25.4, 76.2, and 127.0 mm positive elevations. Lastly, predicting results from an analytical model with the newly added features at a positive elevation were compared with the experimental results obtained at a 76.2 mm positive elevation. The model prediction and the experimental data agree well, which means the operating mechanisms were understood and captured in the model. This is the first study of a loop heat pipe focusing on a positive elevation, which unveils the unique temperature trend at low heat load operating conditions.
•A loop heat pipe was studied experimentally using neutron radiography.•A gravity-controlled operating mode at a positive elevation was presented.•An analytical model was formulated to predict steady state performance.•Analytical model and experimental data showed agreement at a positive elevation.•The mechanism explains the unique steady state trend at a positive elevation. |
---|---|
ISSN: | 1290-0729 1778-4166 |
DOI: | 10.1016/j.ijthermalsci.2013.10.010 |