Two-phase hollow fiber liquid phase microextraction based on magnetofluid for simultaneous determination of Echinacoside, Tubuloside B, Acteoside and Isoacteoside in rat plasma after oral administration of Cistanche salsa extract by high performance liquid chromatography

Basic apparatus used for hollow fiber liquid phase microextraction: (A) conventional hollow fiber liquid phase microextraction and (B) hollow fiber liquid phase microextraction based on magnetofluid. •A two-phase hollow fiber liquid phase microextraction based on magnetofluid was developed.•The meth...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of pharmaceutical and biomedical analysis 2014-06, Vol.94, p.30-35
Hauptverfasser: Zhou, Jun, Zhang, Qiong, Sun, Jiang Bing, Sun, Xiao Li, Zeng, Ping
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Basic apparatus used for hollow fiber liquid phase microextraction: (A) conventional hollow fiber liquid phase microextraction and (B) hollow fiber liquid phase microextraction based on magnetofluid. •A two-phase hollow fiber liquid phase microextraction based on magnetofluid was developed.•The method separated and determined the four main PhGs of Cistanche salsa extract in vivo.•The method is capable to get a higher enrichment ratio in a short time. A new and fast sample preparation technique based on two-phase hollow fiber liquid phase microextraction (HF-LPME) with magnetofluid was developed to quantitate and determine the four phenylethanoid glycosides (PhGs) (Echinacoside, Tubuloside B, Acteoside and Isoacteoside) in plasma after oral administration of Cistanche salsa extract. Analysis was accomplished by reversed-phase high performance liquid chromatography (RP-HPLC) with ultraviolet detection. Parameters that affect the HF-LPME processes, such as the content of magnetic powder, the solvent type, salt content, stirring speed, extraction time and hollow fiber length, were investigated and optimized. Under the optimized conditions, the preconcentration factors for PhGs were higher than 625. The calibration curve for PhGs was linear in the range of 0.1–100ngmL−1 with correlation coefficients greater than 0.9996. The intra-day and inter-day precision (RSD) were below 8.74% and the limits of detection (LOD) for the four PhGs were 8–15pgmL−1 (S/N=3). The validated method was successfully applied to separate and determine the four PhGs in rat plasma after oral administration of C. salsa extract.
ISSN:0731-7085
1873-264X
DOI:10.1016/j.jpba.2014.01.013