Bilayer lipid membrane-based electrochemical biosensors
This paper presents a brief review on the bilayer lipid membrane (BLM) system and its potential applications as a chemical/biosensor. The applications reviewed include substrate‐enzyme complexes, antigen‐antibody‐complement interactions, electrochemical assay of drugs, as well as light‐sensitive BLM...
Gespeichert in:
Veröffentlicht in: | Journal of clinical laboratory analysis 1988, Vol.2 (4), p.256-264 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 264 |
---|---|
container_issue | 4 |
container_start_page | 256 |
container_title | Journal of clinical laboratory analysis |
container_volume | 2 |
creator | Tien, H. Ti |
description | This paper presents a brief review on the bilayer lipid membrane (BLM) system and its potential applications as a chemical/biosensor. The applications reviewed include substrate‐enzyme complexes, antigen‐antibody‐complement interactions, electrochemical assay of drugs, as well as light‐sensitive BLMs for optical sensors. Suggestions for improvements in the development of BLM‐based electrochemical biosensors for the clinical setting are also presented. |
doi_str_mv | 10.1002/jcla.1860020414 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_15100833</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>15100833</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4284-7b2065523dfff51b85b63fc8b26ae4412c5ece7936fd64f65a555f158202002d3</originalsourceid><addsrcrecordid>eNqFkE1PAjEQhhujiYieve7J20I_tt0ST0gERYIJ8SPx0nS701jssthClH_vkjUaT55mDu8zmfdB6JzgHsGY9pfG6x6RotlxRrID1CF4IFMqKT9EHSxlnkpM2DE6iXGJMZYDIjoov3Je7yAk3q1dmVRQFUGvIC10hDIBD2YTavMKlTPaJ4WrI6xiHeIpOrLaRzj7nl30OL5-GN2ks_vJ7Wg4S01GZZbmBcWCc8pKay0nheSFYNbIggoNWUao4WAgHzBhS5FZwTXn3BIuadMC05J10UV7dx3q9y3EjapcNOB982S9jYrwprxkrAn226AJdYwBrFoHV-mwUwSrvSC1F6R-BTXEZUt8OA-7_-JqOpoN_9BpS7u4gc8fWoc3JXKWc_U8n6i7p_FiMV28qDn7Ak95eWI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>15100833</pqid></control><display><type>article</type><title>Bilayer lipid membrane-based electrochemical biosensors</title><source>Wiley Online Library Journals Frontfile Complete</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Tien, H. Ti</creator><creatorcontrib>Tien, H. Ti</creatorcontrib><description>This paper presents a brief review on the bilayer lipid membrane (BLM) system and its potential applications as a chemical/biosensor. The applications reviewed include substrate‐enzyme complexes, antigen‐antibody‐complement interactions, electrochemical assay of drugs, as well as light‐sensitive BLMs for optical sensors. Suggestions for improvements in the development of BLM‐based electrochemical biosensors for the clinical setting are also presented.</description><identifier>ISSN: 0887-8013</identifier><identifier>EISSN: 1098-2825</identifier><identifier>DOI: 10.1002/jcla.1860020414</identifier><language>eng</language><publisher>New York: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>antibody ; antigen ; electrochemistry ; immunology ; Langmuir films ; lipid bilayers ; membranes ; monolayers ; reviews ; sensors</subject><ispartof>Journal of clinical laboratory analysis, 1988, Vol.2 (4), p.256-264</ispartof><rights>Copyright © 1988 Wiley Periodicals, Inc., A Wiley Company</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4284-7b2065523dfff51b85b63fc8b26ae4412c5ece7936fd64f65a555f158202002d3</citedby><cites>FETCH-LOGICAL-c4284-7b2065523dfff51b85b63fc8b26ae4412c5ece7936fd64f65a555f158202002d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjcla.1860020414$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjcla.1860020414$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,778,782,1414,4012,27910,27911,27912,45561,45562</link.rule.ids></links><search><creatorcontrib>Tien, H. Ti</creatorcontrib><title>Bilayer lipid membrane-based electrochemical biosensors</title><title>Journal of clinical laboratory analysis</title><addtitle>J. Clin. Lab. Anal</addtitle><description>This paper presents a brief review on the bilayer lipid membrane (BLM) system and its potential applications as a chemical/biosensor. The applications reviewed include substrate‐enzyme complexes, antigen‐antibody‐complement interactions, electrochemical assay of drugs, as well as light‐sensitive BLMs for optical sensors. Suggestions for improvements in the development of BLM‐based electrochemical biosensors for the clinical setting are also presented.</description><subject>antibody</subject><subject>antigen</subject><subject>electrochemistry</subject><subject>immunology</subject><subject>Langmuir films</subject><subject>lipid bilayers</subject><subject>membranes</subject><subject>monolayers</subject><subject>reviews</subject><subject>sensors</subject><issn>0887-8013</issn><issn>1098-2825</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1988</creationdate><recordtype>article</recordtype><recordid>eNqFkE1PAjEQhhujiYieve7J20I_tt0ST0gERYIJ8SPx0nS701jssthClH_vkjUaT55mDu8zmfdB6JzgHsGY9pfG6x6RotlxRrID1CF4IFMqKT9EHSxlnkpM2DE6iXGJMZYDIjoov3Je7yAk3q1dmVRQFUGvIC10hDIBD2YTavMKlTPaJ4WrI6xiHeIpOrLaRzj7nl30OL5-GN2ks_vJ7Wg4S01GZZbmBcWCc8pKay0nheSFYNbIggoNWUao4WAgHzBhS5FZwTXn3BIuadMC05J10UV7dx3q9y3EjapcNOB982S9jYrwprxkrAn226AJdYwBrFoHV-mwUwSrvSC1F6R-BTXEZUt8OA-7_-JqOpoN_9BpS7u4gc8fWoc3JXKWc_U8n6i7p_FiMV28qDn7Ak95eWI</recordid><startdate>1988</startdate><enddate>1988</enddate><creator>Tien, H. Ti</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>M7Z</scope><scope>P64</scope></search><sort><creationdate>1988</creationdate><title>Bilayer lipid membrane-based electrochemical biosensors</title><author>Tien, H. Ti</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4284-7b2065523dfff51b85b63fc8b26ae4412c5ece7936fd64f65a555f158202002d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1988</creationdate><topic>antibody</topic><topic>antigen</topic><topic>electrochemistry</topic><topic>immunology</topic><topic>Langmuir films</topic><topic>lipid bilayers</topic><topic>membranes</topic><topic>monolayers</topic><topic>reviews</topic><topic>sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tien, H. Ti</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biochemistry Abstracts 1</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Journal of clinical laboratory analysis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tien, H. Ti</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Bilayer lipid membrane-based electrochemical biosensors</atitle><jtitle>Journal of clinical laboratory analysis</jtitle><addtitle>J. Clin. Lab. Anal</addtitle><date>1988</date><risdate>1988</risdate><volume>2</volume><issue>4</issue><spage>256</spage><epage>264</epage><pages>256-264</pages><issn>0887-8013</issn><eissn>1098-2825</eissn><abstract>This paper presents a brief review on the bilayer lipid membrane (BLM) system and its potential applications as a chemical/biosensor. The applications reviewed include substrate‐enzyme complexes, antigen‐antibody‐complement interactions, electrochemical assay of drugs, as well as light‐sensitive BLMs for optical sensors. Suggestions for improvements in the development of BLM‐based electrochemical biosensors for the clinical setting are also presented.</abstract><cop>New York</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><doi>10.1002/jcla.1860020414</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0887-8013 |
ispartof | Journal of clinical laboratory analysis, 1988, Vol.2 (4), p.256-264 |
issn | 0887-8013 1098-2825 |
language | eng |
recordid | cdi_proquest_miscellaneous_15100833 |
source | Wiley Online Library Journals Frontfile Complete; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals |
subjects | antibody antigen electrochemistry immunology Langmuir films lipid bilayers membranes monolayers reviews sensors |
title | Bilayer lipid membrane-based electrochemical biosensors |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T18%3A46%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Bilayer%20lipid%20membrane-based%20electrochemical%20biosensors&rft.jtitle=Journal%20of%20clinical%20laboratory%20analysis&rft.au=Tien,%20H.%20Ti&rft.date=1988&rft.volume=2&rft.issue=4&rft.spage=256&rft.epage=264&rft.pages=256-264&rft.issn=0887-8013&rft.eissn=1098-2825&rft_id=info:doi/10.1002/jcla.1860020414&rft_dat=%3Cproquest_cross%3E15100833%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=15100833&rft_id=info:pmid/&rfr_iscdi=true |