Bilayer lipid membrane-based electrochemical biosensors

This paper presents a brief review on the bilayer lipid membrane (BLM) system and its potential applications as a chemical/biosensor. The applications reviewed include substrate‐enzyme complexes, antigen‐antibody‐complement interactions, electrochemical assay of drugs, as well as light‐sensitive BLM...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical laboratory analysis 1988, Vol.2 (4), p.256-264
1. Verfasser: Tien, H. Ti
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 264
container_issue 4
container_start_page 256
container_title Journal of clinical laboratory analysis
container_volume 2
creator Tien, H. Ti
description This paper presents a brief review on the bilayer lipid membrane (BLM) system and its potential applications as a chemical/biosensor. The applications reviewed include substrate‐enzyme complexes, antigen‐antibody‐complement interactions, electrochemical assay of drugs, as well as light‐sensitive BLMs for optical sensors. Suggestions for improvements in the development of BLM‐based electrochemical biosensors for the clinical setting are also presented.
doi_str_mv 10.1002/jcla.1860020414
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_15100833</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>15100833</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4284-7b2065523dfff51b85b63fc8b26ae4412c5ece7936fd64f65a555f158202002d3</originalsourceid><addsrcrecordid>eNqFkE1PAjEQhhujiYieve7J20I_tt0ST0gERYIJ8SPx0nS701jssthClH_vkjUaT55mDu8zmfdB6JzgHsGY9pfG6x6RotlxRrID1CF4IFMqKT9EHSxlnkpM2DE6iXGJMZYDIjoov3Je7yAk3q1dmVRQFUGvIC10hDIBD2YTavMKlTPaJ4WrI6xiHeIpOrLaRzj7nl30OL5-GN2ks_vJ7Wg4S01GZZbmBcWCc8pKay0nheSFYNbIggoNWUao4WAgHzBhS5FZwTXn3BIuadMC05J10UV7dx3q9y3EjapcNOB982S9jYrwprxkrAn226AJdYwBrFoHV-mwUwSrvSC1F6R-BTXEZUt8OA-7_-JqOpoN_9BpS7u4gc8fWoc3JXKWc_U8n6i7p_FiMV28qDn7Ak95eWI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>15100833</pqid></control><display><type>article</type><title>Bilayer lipid membrane-based electrochemical biosensors</title><source>Wiley Online Library Journals Frontfile Complete</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Tien, H. Ti</creator><creatorcontrib>Tien, H. Ti</creatorcontrib><description>This paper presents a brief review on the bilayer lipid membrane (BLM) system and its potential applications as a chemical/biosensor. The applications reviewed include substrate‐enzyme complexes, antigen‐antibody‐complement interactions, electrochemical assay of drugs, as well as light‐sensitive BLMs for optical sensors. Suggestions for improvements in the development of BLM‐based electrochemical biosensors for the clinical setting are also presented.</description><identifier>ISSN: 0887-8013</identifier><identifier>EISSN: 1098-2825</identifier><identifier>DOI: 10.1002/jcla.1860020414</identifier><language>eng</language><publisher>New York: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>antibody ; antigen ; electrochemistry ; immunology ; Langmuir films ; lipid bilayers ; membranes ; monolayers ; reviews ; sensors</subject><ispartof>Journal of clinical laboratory analysis, 1988, Vol.2 (4), p.256-264</ispartof><rights>Copyright © 1988 Wiley Periodicals, Inc., A Wiley Company</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4284-7b2065523dfff51b85b63fc8b26ae4412c5ece7936fd64f65a555f158202002d3</citedby><cites>FETCH-LOGICAL-c4284-7b2065523dfff51b85b63fc8b26ae4412c5ece7936fd64f65a555f158202002d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjcla.1860020414$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjcla.1860020414$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,778,782,1414,4012,27910,27911,27912,45561,45562</link.rule.ids></links><search><creatorcontrib>Tien, H. Ti</creatorcontrib><title>Bilayer lipid membrane-based electrochemical biosensors</title><title>Journal of clinical laboratory analysis</title><addtitle>J. Clin. Lab. Anal</addtitle><description>This paper presents a brief review on the bilayer lipid membrane (BLM) system and its potential applications as a chemical/biosensor. The applications reviewed include substrate‐enzyme complexes, antigen‐antibody‐complement interactions, electrochemical assay of drugs, as well as light‐sensitive BLMs for optical sensors. Suggestions for improvements in the development of BLM‐based electrochemical biosensors for the clinical setting are also presented.</description><subject>antibody</subject><subject>antigen</subject><subject>electrochemistry</subject><subject>immunology</subject><subject>Langmuir films</subject><subject>lipid bilayers</subject><subject>membranes</subject><subject>monolayers</subject><subject>reviews</subject><subject>sensors</subject><issn>0887-8013</issn><issn>1098-2825</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1988</creationdate><recordtype>article</recordtype><recordid>eNqFkE1PAjEQhhujiYieve7J20I_tt0ST0gERYIJ8SPx0nS701jssthClH_vkjUaT55mDu8zmfdB6JzgHsGY9pfG6x6RotlxRrID1CF4IFMqKT9EHSxlnkpM2DE6iXGJMZYDIjoov3Je7yAk3q1dmVRQFUGvIC10hDIBD2YTavMKlTPaJ4WrI6xiHeIpOrLaRzj7nl30OL5-GN2ks_vJ7Wg4S01GZZbmBcWCc8pKay0nheSFYNbIggoNWUao4WAgHzBhS5FZwTXn3BIuadMC05J10UV7dx3q9y3EjapcNOB982S9jYrwprxkrAn226AJdYwBrFoHV-mwUwSrvSC1F6R-BTXEZUt8OA-7_-JqOpoN_9BpS7u4gc8fWoc3JXKWc_U8n6i7p_FiMV28qDn7Ak95eWI</recordid><startdate>1988</startdate><enddate>1988</enddate><creator>Tien, H. Ti</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>M7Z</scope><scope>P64</scope></search><sort><creationdate>1988</creationdate><title>Bilayer lipid membrane-based electrochemical biosensors</title><author>Tien, H. Ti</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4284-7b2065523dfff51b85b63fc8b26ae4412c5ece7936fd64f65a555f158202002d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1988</creationdate><topic>antibody</topic><topic>antigen</topic><topic>electrochemistry</topic><topic>immunology</topic><topic>Langmuir films</topic><topic>lipid bilayers</topic><topic>membranes</topic><topic>monolayers</topic><topic>reviews</topic><topic>sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tien, H. Ti</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biochemistry Abstracts 1</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Journal of clinical laboratory analysis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tien, H. Ti</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Bilayer lipid membrane-based electrochemical biosensors</atitle><jtitle>Journal of clinical laboratory analysis</jtitle><addtitle>J. Clin. Lab. Anal</addtitle><date>1988</date><risdate>1988</risdate><volume>2</volume><issue>4</issue><spage>256</spage><epage>264</epage><pages>256-264</pages><issn>0887-8013</issn><eissn>1098-2825</eissn><abstract>This paper presents a brief review on the bilayer lipid membrane (BLM) system and its potential applications as a chemical/biosensor. The applications reviewed include substrate‐enzyme complexes, antigen‐antibody‐complement interactions, electrochemical assay of drugs, as well as light‐sensitive BLMs for optical sensors. Suggestions for improvements in the development of BLM‐based electrochemical biosensors for the clinical setting are also presented.</abstract><cop>New York</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><doi>10.1002/jcla.1860020414</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0887-8013
ispartof Journal of clinical laboratory analysis, 1988, Vol.2 (4), p.256-264
issn 0887-8013
1098-2825
language eng
recordid cdi_proquest_miscellaneous_15100833
source Wiley Online Library Journals Frontfile Complete; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects antibody
antigen
electrochemistry
immunology
Langmuir films
lipid bilayers
membranes
monolayers
reviews
sensors
title Bilayer lipid membrane-based electrochemical biosensors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T18%3A46%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Bilayer%20lipid%20membrane-based%20electrochemical%20biosensors&rft.jtitle=Journal%20of%20clinical%20laboratory%20analysis&rft.au=Tien,%20H.%20Ti&rft.date=1988&rft.volume=2&rft.issue=4&rft.spage=256&rft.epage=264&rft.pages=256-264&rft.issn=0887-8013&rft.eissn=1098-2825&rft_id=info:doi/10.1002/jcla.1860020414&rft_dat=%3Cproquest_cross%3E15100833%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=15100833&rft_id=info:pmid/&rfr_iscdi=true