Family perceptions of insulin pump adverse events in children and adolescents
Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidenc...
Gespeichert in:
Veröffentlicht in: | Diabetes technology & therapeutics 2014-04, Vol.16 (4), p.204-207 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidence in dealing with them.
We approached all families of children and adolescents ≤ 19 years of age on CSII attending the diabetes clinic over a 16-week clinic cycle. Participants completed a retrospective questionnaire examining issues over the previous 12 months. Data on pump adverse events as well as answers to questions pertaining to education and confidence were collected.
Our survey received a response rate of 99%, with 235 of the 238 families approached participating. In the preceding 12 months, 104 of 230 (45%) had reported at least one pump-related adverse event (either mechanical or set-related), with an associated 52 of 229 (23%) resulting in pump replacement. This equated to a minimum incidence density of 53 adverse events/100 person-years. Additionally, 18 of 230 (8%) reported a hospital admission or emergency department attendance as a consequence. Pump malfunction and infusion set/site failures were the most common events reported, with one or more events in 58 of 104 (56%) and 47 of 104 (45%), respectively. Adverse events, excluding set/site failures, were associated with older age (13.1 ± 3.4 years vs. 11.9 ± 4 years; P = 0.02).
This is the first study to look at family perceptions of adverse events while using modern CSII. It highlights a high self-reported rate of CSII-related adverse events, pump replacement, and subsequent presentation to the hospital. Potential areas for additional targeted education are identified. Further prospective study examining pump adverse event characteristics and incidence is warranted. |
---|---|