•A dedicated detritiation process for highly tritiated water (HTW) has to be identified.•Water gas shift and isotopic swamping via Pd–Ag membrane reactor are possible processes.•A parametric analysis through two simulation codes is performed.•A comparison in terms of the decontamination factor is pr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Fusion engineering and design 2013-10, Vol.88 (9-10), p.2413-2416
Hauptverfasser: Santucci, Alessia, Rizzello, Claudio, Tosti, Silvano
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•A dedicated detritiation process for highly tritiated water (HTW) has to be identified.•Water gas shift and isotopic swamping via Pd–Ag membrane reactor are possible processes.•A parametric analysis through two simulation codes is performed.•A comparison in terms of the decontamination factor is provided. In a D–T fusion machine, due to the possible reaction between tritium and oxygen, some potential sources of highly tritiated water (HTW) can be identified. Therefore, a dedicated detritiation process has to be assessed either for economic and safety reasons. In this view, the use of a Pd-based membrane reactor performing isotopic exchange reactions can be considered since hydrogen isotopes exclusively permeate the Pd–Ag membrane and their exchange over the catalyst realizes the water detritiation. In this activity, the treatment of highly tritiated water, generated by an ITER-like machine (i.e. 2kg of stoichiometric HTO containing up to 300g of tritium), via a Pd-membrane reactor is studied in terms of decontamination capability. Especially, a parametric analysis of two processes (water gas shift and isotopic swamping) performed in a Pd-based membrane reactor is carried out by using two mathematical models previously developed and experimentally verified. Particularly, the effect of the reactor temperature, the membrane thickness, the reaction pressure and the protium sweep flow-rate is investigated. Moreover, a comparison in terms of the decontamination factor and the number of reactors necessary to detritiate the HTW are provided. Generally, the results reveal a higher decontamination capability of the WGS reaction respect with the IS (maximum DF values of about 120 and 1.6 in the case of WGS and IS, respectively). However some drawbacks, mainly related with the formation of tritiated species, can occur by performing the WGS.
ISSN:0920-3796
1873-7196
DOI:10.1016/j.fusengdes.2013.05.080