High-dose-rate prostate brachytherapy based on registered transrectal ultrasound and in-room cone-beam CT images

Abstract Purpose To present a high-dose-rate (HDR) brachytherapy procedure for prostate cancer using transrectal ultrasound (TRUS) to contour the regions of interest and registered in-room cone-beam CT (CBCT) images for needle reconstruction. To characterize the registration uncertainties between th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Brachytherapy 2014-03, Vol.13 (2), p.128-136
Hauptverfasser: Even, Aniek J.G, Nuver, Tonnis T, Westendorp, Hendrik, Hoekstra, Carel J, Slump, Cornelis H, Minken, André W
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Purpose To present a high-dose-rate (HDR) brachytherapy procedure for prostate cancer using transrectal ultrasound (TRUS) to contour the regions of interest and registered in-room cone-beam CT (CBCT) images for needle reconstruction. To characterize the registration uncertainties between the two imaging modalities and explore the possibility of performing the procedure solely on TRUS. Methods and Materials Patients were treated with a TRUS/CBCT-based HDR brachytherapy procedure. For 100 patients, dosimetric results were analyzed. For 40 patients, registration uncertainties were examined by determining differences in fiducial marker positions on TRUS and registered CBCT. The accuracy of needle reconstruction on TRUS was investigated by determining the position differences of needle tips on TRUS and CBCT. The dosimetric impact of reregistration and needle reconstruction on TRUS only was studied for 8 patients. Results The average prostate V100 was 97.8%, urethra D10 was 116.3%, and rectum D1 cc was 66.4% of the prescribed dose. For 85% of the patients, registration inaccuracies were within 3 mm. Large differences were found between needle tips on TRUS and CBCT, especially in cranial–caudal direction, with a maximum of 10.4 mm. Reregistration resulted in a maximum V100 reduction of 0.9%, whereas needle reconstruction on TRUS only gave a maximum reduction of 9.4%. Conclusions HDR prostate brachytherapy based on TRUS combined with CBCT is an accurate method. Registration uncertainties, and consequently dosimetric inaccuracies, are small compared with the uncertainties of performing the procedure solely based on static TRUS images. CBCT imaging is a requisite in our current procedure.
ISSN:1538-4721
1873-1449
DOI:10.1016/j.brachy.2013.08.001