Diagnostic Accuracy of 18F Choline PET/CT using Time-of-Flight Reconstruction Algorithm in Prostate Cancer Patients With Biochemical Recurrence
PURPOSEImage quality (IQ) of PET in voluminous body regions can be limited, which impairs the assessment of small metastatic lesions. Time-of-flight (TOF) reconstruction algorithm may deliver an increase of spatial resolution. The purpose of this study was to evaluate the impact of TOF on IQ, lesion...
Gespeichert in:
Veröffentlicht in: | Clinical nuclear medicine 2014-03, Vol.39 (3), p.e197-e201 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | PURPOSEImage quality (IQ) of PET in voluminous body regions can be limited, which impairs the assessment of small metastatic lesions. Time-of-flight (TOF) reconstruction algorithm may deliver an increase of spatial resolution. The purpose of this study was to evaluate the impact of TOF on IQ, lesion detection rate, lesion volume (V) and SUVmax in F choline PET/CT of prostate cancer patients with biochemical recurrence compared to standard PET/CT reconstruction (standard).
PATIENTS AND MATERIALSDuring a period of 9 months, 32 patients with prostate cancer (mean [SD] age, 71 [7.8] years) and biochemical recurrence were included in this prospective institutional review board–approved study. Each patient underwent a state-of-the-art 3-dimensional F choline PET/CT. A total of 76 lesions were assessed by 2 board-certified nuclear medicine physicians and a third-year resident. Lesion volume and SUVmax of local recurrence, lymph nodes, and organ metastases were compared between TOF and standard. Image quality and lesion demarcation were rated according to a 5-point Likert-type scale. Interobserver agreement was assessed.
RESULTSEight additional lesions were detected using TOF (SUVmax, 3.64 [0.95]; V, 0.58 cm [0.50]). Image quality was reduced (IQ standard, 1.28; TOF, 1.77; P < 0.01) in calculated TOF images, although quality of lesion demarcation was improved (lesion demarcationstandard, 1.66; TOF, 1.26; P < 0.01). SUVmax was significantly increased in TOF images (SUVmax standard, 6.9 [4.1]; TOF, 8.1 [4.1]; P < 0.01), whereas V did not show significant differences (V standard, 5.3 [10.4] cm; TOF, 5.4 [10.3] cm; P = 0.41). Interobserver agreement was good for combined ratings (1 + 2 and 3 + 4).
CONCLUSIONSApplication of TOF seems to be of additional value to detect small metastatic lesions in patients with prostate cancer and biochemical recurrence, which may have further clinical implications for secondary treatment. |
---|---|
ISSN: | 0363-9762 1536-0229 |
DOI: | 10.1097/RLU.0b013e3182a23d37 |