Patient-tailored scan delay for multiphase liver CT: improved scan quality and lesion conspicuity with a novel timing bolus method

The purpose of this study was to compare scan quality and lesion conspicuity for late arterial and portal venous phase liver CT scans using fixed versus patient-tailored scan delay derived with an evidence-based timing bolus method. We retrospectively identified the cases of 73 patients who underwen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of roentgenology (1976) 2014-02, Vol.202 (2), p.318-323
Hauptverfasser: Schneider, J Gabriel, Wang, Zhen J, Wang, Wilbur, Yee, Judy, Fu, Yanjun, Yeh, Benjamin M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The purpose of this study was to compare scan quality and lesion conspicuity for late arterial and portal venous phase liver CT scans using fixed versus patient-tailored scan delay derived with an evidence-based timing bolus method. We retrospectively identified the cases of 73 patients who underwent both multiphase liver CT with fixed late arterial and portal venous phase scan delay times of 45 and 80 seconds and subsequent multiphase liver CT with patient-tailored scan delay determined with a timing bolus and a previously reported relation between the time to peak aortic and liver enhancement. Both late arterial and portal venous phase scans were graded in terms of scan quality. Hepatic lesion conspicuity (difference in attenuation between lesion and liver parenchyma) for hypervascular lesions (late arterial phase) and hypovascular lesions (portal venous phase) was recorded. Patient-tailored scan delay reflected a wide range of times to peak aortic enhancement (mean, 24 seconds; range, 18-32 seconds) and yielded a greater proportion of optimal scans compared with fixed scan delay for both late arterial phase (92% versus 74%, p < 0.01) and portal venous phase (86% versus 70%, p < 0.05) scans. Mean hypervascular lesion conspicuity was greater for lesions imaged with patient-tailored scan delay rather than fixed scan delay (84.0 versus 57.0 HU, p < 0.01). Compared with examinations with fixed scan delay, multiphase liver CT that incorporates patient-tailored scan delay produces more optimally timed late arterial and portal venous phase CT scans with greater lesion conspicuity.
ISSN:0361-803X
1546-3141
DOI:10.2214/AJR.12.9676