Non-calcified coronary atherosclerotic plaque visualization on CT: effects of contrast-enhancement and lipid-content fractions

Computed tomography (CT) may characterize lipid-rich and presumably rupture-prone non-calcified coronary atherosclerotic plaque based on its Hounsfield-Unit (HU), but still inconclusively. This study aimed to evaluate factors influencing the HU-value of non-calcified plaque using software simulation...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International Journal of Cardiovascular Imaging 2013-06, Vol.29 (5), p.1137-1148
Hauptverfasser: Kristanto, Wisnumurti, van Ooijen, Peter M. A., Greuter, Marcel J. W., Groen, Jaap M., Vliegenthart, Rozemarijn, Oudkerk, Matthijs
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Computed tomography (CT) may characterize lipid-rich and presumably rupture-prone non-calcified coronary atherosclerotic plaque based on its Hounsfield-Unit (HU), but still inconclusively. This study aimed to evaluate factors influencing the HU-value of non-calcified plaque using software simulation. Several realistic virtual plaqueburdened coronary phantoms were constructed at 5 μm resolution. CT scanning was simulated with settings resembling a 64-row multi-detector CT (64-MDCT) and reconstructed at 64-MDCT (0.4 mm) and MicroCT (48 μm) resolutions. Influences of lumen contrast-enhancement, stenosis-grades, and plaque compositions on plaque visualization were analyzed. Lumen contrast-enhancement and mean plaque HU-value were positively correlated (R 2  > 0.92), with approximately the same slopes for all plaque compositions. Percentage lipid-content and mean plaque HU-value were negatively correlated (R 2  > 0.98). Stenosis-grade and noise had minimal influence on the correlations. Influence of lumen contrast-enhancement on plaque HU-value was following a specific exponentially declining pattern (y = Ae −λx  + c) from the lumen border until 2-pixel radius. Outside 2-pixel radius, plaque HU-values deviated maximally 5 HU from non-contrast-enhanced reference. Thus, to avoid lumen contrast-enhancement influence, plaques should be measured outside 2-pixel radius from the lumen border. Based on the patterns found, a lumen influence correction algorithm may be developed. HU-based plaque percentage lipid-content determination might serve as an alternative plaque characterization method. However, its applicability is still hindered by many inherent limitations.
ISSN:1569-5794
1573-0743
1875-8312
DOI:10.1007/s10554-012-0176-4