Hydroxyapatite and Collagen Combination-Coated Dental Implants Display Better Bone Formation in the Peri-Implant Area Than the Same Combination Plus Bone Morphogenetic Protein-2–Coated Implants, Hydroxyapatite Only Coated Implants, and Uncoated Implants
Purpose The objective of this study was to compare peri-implant bone formation among uncoated (UC), hydroxyapatite (HA), collagen plus HA (CH), and collagen, HA, plus bone morphogenetic protein-2 (BMP-2) implant groups. Materials and Methods Implants in the UC group had acid-etched surfaces. The sur...
Gespeichert in:
Veröffentlicht in: | Journal of oral and maxillofacial surgery 2014, Vol.72 (1), p.53-60 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose The objective of this study was to compare peri-implant bone formation among uncoated (UC), hydroxyapatite (HA), collagen plus HA (CH), and collagen, HA, plus bone morphogenetic protein-2 (BMP-2) implant groups. Materials and Methods Implants in the UC group had acid-etched surfaces. The surface coating was applied using the aerosol deposition method. The coated surfaces were examined by scanning electron microscopy, x-ray diffraction (XRD), and Fourier-transformed infrared absorption analysis. Subsequently, 6 implants from each group (total, 24 implants) were installed in the tibias of rabbits. The animals were sacrificed at 6 weeks after implant installation. Peri-implant bone formation and bone-to-implant contact (BIC) were measured in histologic sections. Significant differences among groups were evaluated using analysis of variance. Results Based on the measured XRD patterns, there was a characteristic HA phase (International Centre for Diffraction Data [ICDD], 086-0740) coated on the titanium (ICDD, 089-3725). Subsequent coating processes for collagen and BMP-2 did not display additional diffraction peaks, but maintained the diffraction patterns of the HA-coated titanium. The presence of collagen was verified by infrared absorption analysis. When comparing these modifications with UC surfaces, only the CH coating displayed significantly greater peri-implant bone formation and BIC ( P = .003 and P < .001, respectively). Adding BMP-2 to the implant surface did not produce any advantage compared with the CH coating. Conclusions In this study, the CH group displayed significantly greater new bone formation and BIC than the other groups. There was no significant difference among the other groups. |
---|---|
ISSN: | 0278-2391 1531-5053 |
DOI: | 10.1016/j.joms.2013.08.031 |