Assessment of line of sight characteristics of ITER bolometer prototype collimators

► Developments on the optimization of line of sight (LOS) characteristics for the ITER bolometry collimators are presented. ► ITER Bolometer Robot Test Facility (IBOROB) is used as a diagnostic tool in order to analyze signal geometry and assess the performance of different prototypes. ► LOS charact...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Fusion engineering and design 2013-10, Vol.88 (6-8), p.1267-1270
Hauptverfasser: Penzel, F., Meister, H., Giannone, L., Kannamüller, M., Koll, J., Trautmann, T., Koch, A.W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:► Developments on the optimization of line of sight (LOS) characteristics for the ITER bolometry collimators are presented. ► ITER Bolometer Robot Test Facility (IBOROB) is used as a diagnostic tool in order to analyze signal geometry and assess the performance of different prototypes. ► LOS characteristics as a function of number of apertures are presented. ► Influence of a microwave filtering aperture was determined. ► Improvement of stray light attenuation by application of the graphite based coating AQUADAG. This work outlines the present design status of developments on the optimization of line of sight (LOS) characteristics for the ITER bolometry collimators. The verification and measurement of the LOS of the bolometry is an important issue for a reliable operation of the tomographic reconstruction algorithms. Therefore the ITER Bolometer Robot Test Facility (IBOROB) is used as a diagnostic tool in order to analyze LOS geometry and assess the performance of different collimator prototypes. The LOS characteristics as a function of number of apertures are presented and the influence of a microwave filtering aperture was determined. The results of the improvement of stray light attenuation by application of the graphite based coating AQUADAG are evaluated as well and an overview about the current collimator design is given. This paper focuses on the most remarkable results, a way to further possible upgrades is outlined. However, some results are not in accordance with the ones predicted in theoretical calculations. Thus not all key parameters which influence the LOS could be clearly identified yet.
ISSN:0920-3796
1873-7196
DOI:10.1016/j.fusengdes.2012.12.027