Uniformity Analysis at MEA and Stack Levels for a Nexa PEMA Fuel Cell System
The Nexa power module is a small, low maintenance, and fully automated fuel cell system designed for integration into portable and back-up power products. The stack features a specified net power output of 1200 W at full load with about 26 V. The power module was evaluated at membrane-electrode-asse...
Gespeichert in:
Veröffentlicht in: | Journal of power sources 2004-04, Vol.128 (2), p.231-231 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The Nexa power module is a small, low maintenance, and fully automated fuel cell system designed for integration into portable and back-up power products. The stack features a specified net power output of 1200 W at full load with about 26 V. The power module was evaluated at membrane-electrode-assembly (MEA) and stack levels, and uniformity analyses were conducted on a 800 W load for all MEAs in 10 individual Nexa stacks. The MEA voltage without external load averages 224 mV higher than that with a load of 800 W. The average difference is 8.8% and the highest is 13.1% between the minimum MEA voltage in the stack and the mean value. |
---|---|
ISSN: | 0378-7753 |