Comparison of instrumental methods for chlorinated dibenzo-p-dioxin (CDD) determination - interim results of a round-robin study involving GC-MS, MS-MS, and high resolution MS

A study was designed to determine the feasibility of using GC-MS-MS techniques for the determination of chlorinated dibenzo-p-dioxins (CDD) and dibenzofurans (CDF) in difficult environmental samples with reduced cleanup. Three fish and three sediment extracts were provided to six different laborator...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemosphere (Oxford) 1986, Vol.15 (9), p.1147-1156
Hauptverfasser: Clement, R.E., Bobbie, B., Taguchi, V.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A study was designed to determine the feasibility of using GC-MS-MS techniques for the determination of chlorinated dibenzo-p-dioxins (CDD) and dibenzofurans (CDF) in difficult environmental samples with reduced cleanup. Three fish and three sediment extracts were provided to six different laboratories with GC-MS-MS capability for analysis. In addition, extracts were analysed by GC-low reduction MS (LRMS) and GC-high resolution MS (HRMS). At the time of this report, all participating GC-MS-MS laboratories had not completed their analysis of the supplied samples. All reporting laboratories found the analysis of these very complex samples difficult without extensive cleanup. GC-HRMS determination of some samples was possible with reduced cleanup compared to GC-LRMS.
ISSN:0045-6535
1879-1298
DOI:10.1016/0045-6535(86)90385-1