Analysis of Temperature's Influence on a Digital Displacement Pump's Volumetric Efficiency
The focus of the current paper is on a small 18 cm3/rev Digital Displacement Pump (DDP), where it is investigated how temperature influency the pump behaviour and static performance. An experimentally validated model of the DDP is presented, which is the basis for the investigation. From the results...
Gespeichert in:
Veröffentlicht in: | Applied mechanics and materials 2012-11, Vol.233 (Fluid Dynamic and Mechanical & Electrical Control Engineering), p.24-27 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The focus of the current paper is on a small 18 cm3/rev Digital Displacement Pump (DDP), where it is investigated how temperature influency the pump behaviour and static performance. An experimentally validated model of the DDP is presented, which is the basis for the investigation. From the results it is found that although the temperature highly influences the pump behaviour it is possible to mostly compensate for this by accurately controlling the closing angle of the low pressure valve. |
---|---|
ISSN: | 1660-9336 1662-7482 1662-7482 |
DOI: | 10.4028/www.scientific.net/AMM.233.24 |