Serial Assessment of Vessel Interactions After Drug-Eluting Stent Implantation in Unprotected Distal Left Main Coronary Artery Disease Using Frequency-Domain Optical Coherence Tomography

Objectives This study sought to assess stent-vessel interactions after drug-eluting stent (DES) implantation in unprotected left main coronary artery (ULM) by frequency-domain optical coherence tomography (FD-OCT). Background Percutaneous coronary intervention using DES in ULM has been increasingly...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JACC. Cardiovascular interventions 2013-10, Vol.6 (10), p.1035-1045
Hauptverfasser: Fujino, Yusuke, MD, Attizzani, Guilherme F., MD, Bezerra, Hiram G., MD, PhD, Wang, Wei, PhD, Tahara, Satoko, MD, PhD, Yamamoto, Hirosada, MD, Chamie, Daniel, MD, Kanaya, Tomoaki, MD, Mehanna, Emile, MD, Takagi, Kensuke, MD, Nakamura, Sunao, MD, PhD, Costa, Marco A., MD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives This study sought to assess stent-vessel interactions after drug-eluting stent (DES) implantation in unprotected left main coronary artery (ULM) by frequency-domain optical coherence tomography (FD-OCT). Background Percutaneous coronary intervention using DES in ULM has been increasingly performed in routine practice. Recently, FD-OCT assessments of DES-vessel interactions have been used as surrogates for DES safety; however, there are no FD-OCT studies in ULM. Methods We prospectively enrolled 33 consecutive patients with ULM disease treated with sirolimus- (n = 11) and everolimus-eluting stents (n = 22). FD-OCT assessments were performed post-percutaneous coronary intervention and at 9-month follow-up. Three different segments of ULM were compared: distal (DIS), bifurcation (BIF), and ostial-body (BODY). The primary endpoints were percentages of uncovered and malapposed struts at 9-month follow-up, and the secondary endpoint was neointimal hyperplasia area. Results We analyzed 25,873 stent struts. Significant differences were demonstrated for percentage of uncovered struts (3.4%, 11.7%, and 18.7%, respectively for DIS, BIF, and BODY; p < 0.05 for all the comparisons). Malapposition was also more common in BODY (5.3%) than in DIS (0.6%) and BIF (2.0%) segments (p < 0.05 for BODY vs. DIS, and BODY vs. BIF). Equivalent neointimal hyperplasia areas were demonstrated in all segments. Acute malapposition rates led to different patterns of DES-vessel interactions at 9-month follow-up. Conclusions Distinct patterns of DES-vessel interactions were demonstrated in different segments of ULM. Acute stent strut malapposition affects these findings.
ISSN:1936-8798
1876-7605
DOI:10.1016/j.jcin.2013.05.015