Thirty-five day Impella 5.0 support via right axillary side graft cannulation for acute cardiogenic shock
We describe the use of an Impella 5.0 for mechanical support in acute cardiogenic shock after an acute myocardial infarction. A 61-year-old man with a history of severe coronary artery disease who underwent coronary artery bypass grafting with ischemic cardiomyopathy presented with cardiogenic shock...
Gespeichert in:
Veröffentlicht in: | Innovations (Philadelphia, Pa.) Pa.), 2013-07, Vol.8 (4), p.307-309 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We describe the use of an Impella 5.0 for mechanical support in acute cardiogenic shock after an acute myocardial infarction. A 61-year-old man with a history of severe coronary artery disease who underwent coronary artery bypass grafting with ischemic cardiomyopathy presented with cardiogenic shock after an ST-elevation myocardial infarction. An Impella Recover LP 5.0 (Abiomed, Danvers, MA USA) was inserted via a right axillary side graft, using transesophageal echocardiographic and fluoroscopic guidance. The patient remained in the intensive care unit, where he required a tracheostomy to be weaned off the ventilator. He required renal replacement therapy with subsequent complete recovery. His Impella support was weaned, and on postoperative day 35, the device was removed. The patient developed axillary thrombosis the morning after removal, requiring thrombectomy. Discharge echocardiogram showed mild left ventricular enlargement with global hypokinesis and left ventricular ejection fraction of 25%. The Impella 5.0 device can safely and effectively be used in the long-term support of cardiogenic shock. |
---|---|
ISSN: | 1556-9845 1559-0879 |
DOI: | 10.1097/IMI.0000000000000009 |