Comparison of integrated whole-body [11C]choline PET/MR with PET/CT in patients with prostate cancer
Purpose To evaluate the performance of conventional [ 11 C]choline PET/CT in comparison to that of simultaneous whole-body PET/MR. Methods The study population comprised 32 patients with prostate cancer who underwent a single-injection dual-imaging protocol with PET/CT and subsequent PET/MR. PET/CT...
Gespeichert in:
Veröffentlicht in: | European journal of nuclear medicine and molecular imaging 2013-10, Vol.40 (10), p.1486-1499 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
To evaluate the performance of conventional [
11
C]choline PET/CT in comparison to that of simultaneous whole-body PET/MR.
Methods
The study population comprised 32 patients with prostate cancer who underwent a single-injection dual-imaging protocol with PET/CT and subsequent PET/MR. PET/CT scans were performed applying standard clinical protocols (5 min after injection of 793 ± 69 MBq [
11
C]choline, 3 min per bed position, intravenous contrast agent). Subsequently (52 ± 15 min after injection) PET/MR was performed (4 min per bed position). PET images were reconstructed iteratively (OSEM 3D), scatter and attenuation correction of emission data and regional allocation of [
11
C]choline foci were performed using CT data for PET/CT and segmented Dixon MR, T1 and T2 sequences for PET/MR. Image quality of the respective PET scans and PET alignment with the respective morphological imaging modality were compared using a four point scale (0–3). Furthermore, number, location and conspicuity of the detected lesions were evaluated. SUVs for suspicious lesions, lung, liver, spleen, vertebral bone and muscle were compared.
Results
Overall 80 lesions were scored visually in 29 of the 32 patients. There was no significant difference between the two PET scans concerning number or conspicuity of the detected lesions (
p
not significant). PET/MR with T1 and T2 sequences performed better than PET/CT in anatomical allocation of lesions (2.87 ± 0.3 vs. 2.72 ± 0.5;
p
= 0.005). The quality of PET/CT images (2.97 ± 0.2) was better than that of the respective PET scan of the PET/MR (2.69 ± 0.5;
p
= 0.007). Overall the maximum and mean lesional SUVs exhibited high correlations between PET/CT and PET/MR (
ρ
= 0.87 and
ρ
= 0.86, respectively; both
p
|
---|---|
ISSN: | 1619-7070 1619-7089 |
DOI: | 10.1007/s00259-013-2467-y |