The effect of a knee ankle foot orthosis incorporating an active knee mechanism on gait of a person with poliomyelitis

Background: The aim of this case study was to identify the effect of a powered stance control knee ankle foot orthosis on the kinematics and temporospatial parameters of walking by a person with poliomyelitis when compared to a knee ankle foot orthosis. Case description and methods: A knee ankle foo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Prosthetics and orthotics international 2013-10, Vol.37 (5), p.411-414
Hauptverfasser: Arazpour, Mokhtar, Chitsazan, Ahmad, Bani, Monireh Ahmadi, Rouhi, Gholamreza, Ghomshe, Farhad Tabatabai, Hutchins, Stephen W
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background: The aim of this case study was to identify the effect of a powered stance control knee ankle foot orthosis on the kinematics and temporospatial parameters of walking by a person with poliomyelitis when compared to a knee ankle foot orthosis. Case description and methods: A knee ankle foot orthosis was initially manufactured by incorporating drop lock knee joints and custom molded ankle foot orthoses and fitted to a person with poliomyelitis. The orthosis was then adapted by adding electrically activated powered knee joints to provide knee extension torque during stance and also flexion torque in swing phase. Lower limb kinematic and kinetic data plus data for temporospatial parameters were acquired from three test walks using each orthosis. Findings and outcomes: Walking speed, step length, and vertical and horizontal displacement of the pelvis decreased when walking with the powered stance control knee ankle foot orthosis compared to the knee ankle foot orthosis. When using the powered stance control knee ankle foot orthosis, the knee flexion achieved during swing and also the overall pattern of walking more closely matched that of normal human walking. The reduced walking speed may have caused the smaller compensatory motions detected when the powered stance control knee ankle foot orthosis was used. Conclusion: The new powered SCKAFO facilitated controlled knee flexion and extension during ambulation for a volunteer poliomyelitis person. Clinical relevance The powered stance control knee ankle foot orthosis has the potential to improve knee joint kinematics in persons with poliomyelitis when ambulating.
ISSN:0309-3646
1746-1553
DOI:10.1177/0309364612469140