Mask versus nasal tube for stabilization of preterm infants at birth: a randomized controlled trial

Positive-pressure ventilation (PPV) using a manual ventilation device and a face mask is recommended for compromised newborn infants in the delivery room (DR). Mask ventilation is associated with airway obstruction and leak. A nasal tube is an alternative interface, but its safety and efficacy have...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pediatrics (Evanston) 2013-08, Vol.132 (2), p.e381-e388
Hauptverfasser: Kamlin, C Omar F, Schilleman, Kim, Dawson, Jennifer A, Lopriore, Enrico, Donath, Susan M, Schmölzer, Georg M, Walther, Frans J, Davis, Peter G, Te Pas, Arjan B
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Positive-pressure ventilation (PPV) using a manual ventilation device and a face mask is recommended for compromised newborn infants in the delivery room (DR). Mask ventilation is associated with airway obstruction and leak. A nasal tube is an alternative interface, but its safety and efficacy have not been tested in extremely preterm infants. An unblinded randomized controlled trial was conducted in Australia, and the Netherlands. Infants were stratified by gestational age (24-25/26-29 weeks) and center. Immediately before birth infants were randomly assigned to receive PPV and/or continuous positive airway pressure with either a nasal tube or a size 00 soft, round silicone mask. Resuscitation protocols were standardized; respiratory support was provided using a T-piece device commencing in room air. Criteria for intubation included need for cardiac compressions, apnea, continuous positive airway pressure >7 cm H2O, and fraction of inspired oxygen >0.4. Primary outcome was endotracheal intubation in the first 24 hours from birth. Three hundred sixty-three infants were randomly assigned; the study terminated early on the grounds of futility. Baseline variables were similar between groups. Intubation rates in the first 24 hours were 54% and 55% in the nasal tube and face mask groups, respectively (odds ratio: 0.97; 95% confidence interval: 0.63-1.50). There were no important differences in any of the secondary outcomes within the whole cohort or between the 2 gestational age subgroups. In infants at
ISSN:0031-4005
1098-4275
DOI:10.1542/peds.2013-0361