Transfacet screw fixation of the subaxial cervical spine—how I do it?

Background Transfacet screw fixation is a biomechanically effective way of fusing the subaxial cervical spine. The technique used by this author is described. Methods With the patient in prone position, a conventional posterior exposure of the cervical spine is done. The entry point used by this aut...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta neurochirurgica 2013-07, Vol.155 (7), p.1235-1239
1. Verfasser: Muthukumar, Natarajan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Transfacet screw fixation is a biomechanically effective way of fusing the subaxial cervical spine. The technique used by this author is described. Methods With the patient in prone position, a conventional posterior exposure of the cervical spine is done. The entry point used by this author is 2 mm above the middle of the lateral mass without any lateral angulation. Under fluoroscopic guidance the facet is drilled until all the four cortical surfaces are purchased. Then the depth is measured to assess the length of the screw required. This is followed by tapping and screw insertion both of which are done under fluoroscopic control. All screws are placed prior to laminectomy to decompress the cervical cord. Conclusions This is a simple, inexpensive and biomechanically effective way of stabilizing the subaxial cervical spine.
ISSN:0001-6268
0942-0940
DOI:10.1007/s00701-013-1730-0