New method of detection for the component of low concentration in water by detector tubes

A technique has been developed for rapid detection of traces of contaminants in water and waste waters using a fine glass tube packed with a solid 'detector reagent' which changes colour with specific elements.A syringe can be used to inject a certain volume of sample into the detector tub...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Water research (Oxford) 1972-01, Vol.6 (11), p.1291-1299
1. Verfasser: Kobayashi, Yoshitaka
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A technique has been developed for rapid detection of traces of contaminants in water and waste waters using a fine glass tube packed with a solid 'detector reagent' which changes colour with specific elements.A syringe can be used to inject a certain volume of sample into the detector tube, or one end of the tube can be dipped into the sample which is allowed to run up inside the tube; the latter is simpler to use, but the injection method is more accurate. detailed procedure is given for detection of specific substances.
ISSN:0043-1354
1879-2448
DOI:10.1016/0043-1354(72)90193-5