The Unreliability of Open Observation Boreholes in Unconfined Aquifer Pumping Tests
ABSTRACT Initial attempts to estimate unconfined aquifer parameters from a pumping test using an open observation borehole proved to be unsuccessful. However, when separate piezometers were installed along a vertical section, significant differences in ground‐water head were noted. These differences...
Gespeichert in:
Veröffentlicht in: | Ground water 1982-01, Vol.20 (5), p.546-550 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ABSTRACT
Initial attempts to estimate unconfined aquifer parameters from a pumping test using an open observation borehole proved to be unsuccessful. However, when separate piezometers were installed along a vertical section, significant differences in ground‐water head were noted. These differences suggest that rather than providing an average ground‐water head, the open borehole provides a means of flow between the different elevations and therefore produces misleading results.
The results for the separate piezometers are analysed using a numerical model, and reasonable values of the aquifer parameters are deduced. |
---|---|