The Unreliability of Open Observation Boreholes in Unconfined Aquifer Pumping Tests

ABSTRACT Initial attempts to estimate unconfined aquifer parameters from a pumping test using an open observation borehole proved to be unsuccessful. However, when separate piezometers were installed along a vertical section, significant differences in ground‐water head were noted. These differences...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ground water 1982-01, Vol.20 (5), p.546-550
Hauptverfasser: Rushton, K. R., Howard, K.W.F.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:ABSTRACT Initial attempts to estimate unconfined aquifer parameters from a pumping test using an open observation borehole proved to be unsuccessful. However, when separate piezometers were installed along a vertical section, significant differences in ground‐water head were noted. These differences suggest that rather than providing an average ground‐water head, the open borehole provides a means of flow between the different elevations and therefore produces misleading results. The results for the separate piezometers are analysed using a numerical model, and reasonable values of the aquifer parameters are deduced.
ISSN:0017-467X
1745-6584