Numerical technique to correct for weak acid errors in gran function analysis of titration data
Ordinary Gran function analysis of titration data from samples which contain weak acids results in overestimates of strong acid acidity and underestimates of weak acid acidity. A numerical technique is developed which solves a general acid-base model from titration data. The technique is an iterativ...
Gespeichert in:
Veröffentlicht in: | Water research (Oxford) 1987, Vol.21 (10), p.1207-1216 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Ordinary Gran function analysis of titration data from samples which contain weak acids results in overestimates of strong acid acidity and underestimates of weak acid acidity. A numerical technique is developed which solves a general acid-base model from titration data. The technique is an iterative procedure which adjusts Gran functions for the effect of the weak acid components. The model and the method are validated with simulated titration data and laboratory data from test solutions. |
---|---|
ISSN: | 0043-1354 1879-2448 |
DOI: | 10.1016/0043-1354(87)90172-2 |