Large animal models in fusionless scoliosis correction research: a literature review

Abstract Background context Numerous prenatal, systemic, or local procedures have been described that have created an experimental scoliosis within different animal species. Compression-based fusionless scoliosis correction devices have been used to induce scoliosis (inverse approach) as an indicati...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The spine journal 2013-06, Vol.13 (6), p.675-688
Hauptverfasser: Roth, Alex K., MSc, Bogie, Rob, MD, Jacobs, Eva, BSc, Arts, Jacobus J., PhD, van Rhijn, Lodewijk W., MD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background context Numerous prenatal, systemic, or local procedures have been described that have created an experimental scoliosis within different animal species. Compression-based fusionless scoliosis correction devices have been used to induce scoliosis (inverse approach) as an indication for their potential corrective efficacy in large animals. Deformities that most closely approximate the three-dimensional nature of an idiopathic-like scoliosis have been created in large animals using a posterior spinal tether. Fusionless scoliosis correction devices have subsequently been tested in these models. Purpose To provide an overview of large animal models used for preclinical testing of fusionless scoliosis correction devices and to describe recent advances in the creation of an idiopathic-like scoliosis large animal model. Study design Literature review of large animal models in fusionless scoliosis correction research. Methods MEDLINE electronic database was searched for studies in which large animal models for spinal or vertebral growth modulation or the creation of an experimental scoliosis were described. The literature search was limited to articles written in the English language. Results The pig appears to be the most suitable animal species for preclinical testing of fusionless scoliosis correction devices because of its large growth potential and the possibility for early weaning. With the inverse approach, it is difficult to gain insight into the possible corrective efficacy of the tested device, and therefore, a two-step approach is preferred. Using a posterior spinal tether, persistent spinal deformities are attained when the deformity has approximately doubled in comparison to the postoperative measure in a time span of approximately 12 weeks. Sufficient tether midline offset is required to render rib procedures unnecessary. Conclusions An idiopathic-like scoliosis animal model can be created using a posterior spinal tether in a fully reversible procedure. Experimental results will need to be reproduced to establish a standard idiopathic-like scoliosis large animal model.
ISSN:1529-9430
1878-1632
DOI:10.1016/j.spinee.2013.02.043