Effect of topical application of tetracaine on intraocular pressure in dogs: Preliminary results

To evaluate the effect of topical application of tetracaine on intraocular pressure (IOP) measurement by Tonopen in dogs. Six healthy male Epagneul Bretons (group 1) and six healthy male black Labrador Retrievers (group 2) were examined. IOP was measured in the right eye (OD) prior to (IOP1) and 1mi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal francais d'ophtalmologie 2013-05, Vol.36 (5), p.402-407
Hauptverfasser: Boillot, T., Gauvin, M., Rosolen, S.-G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To evaluate the effect of topical application of tetracaine on intraocular pressure (IOP) measurement by Tonopen in dogs. Six healthy male Epagneul Bretons (group 1) and six healthy male black Labrador Retrievers (group 2) were examined. IOP was measured in the right eye (OD) prior to (IOP1) and 1minute following instillation of one drop of topical tetracaine (IOP 2), and the left eye (OS) (control) prior to (IOP 3) and 1minute following instillation of one drop of isotonic saline solution (IOP 4). Measurements were performed on two occasions: at 8:00AM and 3:00PM. For both groups, IOP measurements were higher in the morning than in the afternoon. For group 1, IOP1 mean (SD), IOP2 mean (SD), IOP3 mean (SD) and IOP4 mean (SD) were 14.6 (2.2) mmHg, 11.3 (3.2) mmHg, 14.4 (2.2) mmHg and 13.5 (3.9) mmHg respectively, while in group 2, IOP1 mean (SD), IOP2 mean (SD), IOP3 mean (SD) and IOP4 mean (SD) were 14.2 (3.8) mmHg, 9.5 (3.7) mmHg, 13.5 (2.8) mmHg and 13.0 (3.8) mmHg respectively. For both groups at each time point, IOP 2 values were significantly lower (P0.27). This study demonstrates that topical application of tetracaine significantly lowers IOP measured by Tonopen due to a possible interaction with melanin. The potential effect of topical anesthetics should be taken in consideration when performing applanation tonometry for clinical, pharmacological and toxicological studies. Évaluer les effets de l’application topique de tétracaïne sur la mesure de la pression intraoculaire (PIO) au moyen du Tonopen, chez le chien. Six Epagneuls Bretons males, cliniquement normaux (groupe 1) et six Labrador Retrievers males à pelage noir, cliniquement normaux (group 2) ont été examinés. La PIO a été mesurée sur l’œil droit (OD) avant (PIO1) et une minute après instillation d’une goutte de collyre à la tétracaine (PIO2 2), et sur l’œil gauche OS (témoin) avant (PIO 3) et une minute après instillation d’une goutte de solution saline isotonique (PIO 4). Les mesures ont été effectuées à 8heures et à 15heures. Pour les deux groupes, les valeurs de PIO étaient plus élevées le matin que l’après-midi. Pour le groupe 1, les valeurs de la moyenne (écart-type) de la PIO étaient de 14,6 (2,2) mmHg pour la PIO1, 11,3 (3,2) mmHg pour la PIO2, 14,4 (2,2) mmHg pour la PIO3 et 13,5 (3,9) mmHg pour la PIO4 alors que pour le groupe 2, les valeurs de la moyenne (écart-type) de la PIO étaient de 14,2
ISSN:0181-5512
1773-0597