Sweat conductivity test: can it replace chloride titration for cystic fibrosis diagnosis?
Although sweat conductivity values are well matched with chloride concentrations for cystic fibrosis (CF) diagnosis, sweat conductivity is not accepted as a definitive diagnostic tool but only a screening method. The aim of this study was to compare the sweat chloride measurements and sweat conducti...
Gespeichert in:
Veröffentlicht in: | Turkish journal of pediatrics 2012-11, Vol.54 (6), p.576-582 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Although sweat conductivity values are well matched with chloride concentrations for cystic fibrosis (CF) diagnosis, sweat conductivity is not accepted as a definitive diagnostic tool but only a screening method. The aim of this study was to compare the sweat chloride measurements and sweat conductivity values of our patients, and to determine cut-off values of conductivity for making or excluding a CF diagnosis. Fifty-nine CF patients, 10 patients with elevated sweat tests and 69 non-CF patients were included in the study. The mean conductivity values were 123 (64-157) mmol/L, 75.1 (60-93) mmol/L and 39 (18-83) mmol/L in the CF, elevated sweat test and control groups, respectively. The mean chloride concentration values were 107.5 (35-166) mEq/L, 48 (42-76) mEq/L and 25 (11-39) mEq/L in the CF, elevated sweat test and control groups, respectively. Spearman correlation test determined a strong correlation between conductivity and chloride concentration values (r=88%, p |
---|---|
ISSN: | 0041-4301 |