Balancing risk and benefit: maintenance of a thawed Group A plasma inventory for trauma patients requiring massive transfusion

Transfusion of plasma and red blood cell (RBC) units in a balanced ratio approximating 1:1 has been shown in retrospective studies to be associated with improved outcomes for trauma patients. Our low-volume rural trauma center uses a trauma-activated transfusion algorithm. Plasma is thawed upon acti...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The journal of trauma and acute care surgery 2013-06, Vol.74 (6), p.1425-1431
Hauptverfasser: Mehr, Chelsea R, Gupta, Rajan, von Recklinghausen, Friedrich M, Szczepiorkowski, Zbigniew M, Dunbar, Nancy M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Transfusion of plasma and red blood cell (RBC) units in a balanced ratio approximating 1:1 has been shown in retrospective studies to be associated with improved outcomes for trauma patients. Our low-volume rural trauma center uses a trauma-activated transfusion algorithm. Plasma is thawed upon activation to avoid wastage. However, the time required for plasma thawing has made achievement of a 1:1 ratio early in resuscitation challenging. In this study, the time required for plasma thawing is characterized, and a potential solution is proposed. A retrospective chart study of 38 moderately and massively transfused (≥6 U in the first 24 hours) trauma patients admitted from January 2008 to March 2012 was performed. We evaluated the time required to dispense plasma and the number of RBCs dispensed before plasma in these patients. The average time between the dispense of RBCs and plasma was 26 minutes (median, 28; range, 0-48 minutes). The average number of RBCs dispensed before plasma was 8 U (median, 7 U; range, 0-24 U). Nearly one third of massively transfused patients had 10 RBCs or greater dispensed before plasma was available. There exists the potential for delayed plasma availability owing to time required for thawing, which may compromise the ability to provide balanced plasma to RBC transfusion to trauma patients. Maintenance of a thawed Group AB plasma inventory may not be operationally feasible for rural centers with low trauma volumes. Use of a thawed Group A plasma inventory is a potential alternative to ensure rapid plasma availability. Therapeutic study, level V.
ISSN:2163-0755
2163-0763
DOI:10.1097/TA.0b013e31828b813e