Marginal quality of posterior microhybrid resin composite restorations applied using two polymerisation protocols: 5-year randomised split mouth trial
Abstract Objectives This randomised, split-mouth clinical study evaluated the marginal quality of direct Class I and Class II restorations made of microhybrid composite and applied using two polymerisation protocols, using two margin evaluation criteria. Methods A total of 50 patients (mean age: 33...
Gespeichert in:
Veröffentlicht in: | Journal of dentistry 2013-05, Vol.41 (5), p.436-442 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract Objectives This randomised, split-mouth clinical study evaluated the marginal quality of direct Class I and Class II restorations made of microhybrid composite and applied using two polymerisation protocols, using two margin evaluation criteria. Methods A total of 50 patients (mean age: 33 years) received 100 direct Class I or Class II restorations in premolars or molars. Three calibrated operators made the restorations. After conditioning the tooth with 2-step etch-and-rinse adhesive, restorations were made incrementally using microhybrid composite (Tetric EvoCeram). Each layer was polymerised using a polymerisation device operated either at regular mode (600–650 mW/cm2 for 20 s) (RM) or high-power (1200–1300 mW/cm2 for 10 s) mode (HPM). Two independent calibrated operators evaluated the restorations 1 week after restoration placement (baseline), at 6 months and thereafter annually up to 5 years using modified USPHS and SQUACE criteria. Data were analyzed using Mann–Whitney U-test ( α = 0.05). Results Alfa scores (USPHS) for marginal adaptation (86% and 88% for RM and HPM, respectively) and marginal discoloration (88% and 88%, for RM and HPM, respectively) did not show significant differences between the two-polymerisation protocols ( p > 0.05). Alfa scores (SQUACE) for marginal adaptation (88% and 88% for RM and HPM, respectively) and marginal discoloration (94% and 94%, for RM and HPM, respectively) were also not significantly different at 5th year ( p >0.05). Conclusion Regular and high-power polymerisation protocols had no influence on the marginal quality of the microhybrid composite tested up to 5 years. Both modified USPHS and SQUACE criteria confirmed that regardless of the polymerisation mode, marginal quality of the restorations deteriorated compared to baseline. |
---|---|
ISSN: | 0300-5712 1879-176X |
DOI: | 10.1016/j.jdent.2013.02.009 |