Malperfusion in Acute Type A Aortic Dissection: Unsolved Problem

Background Despite a reduced incidence of false lumen perfusion with preferential use of axillary arterial perfusion in acute type A aortic dissection, malperfusion remains a major cause of operative mortality and sequelae. The incidence of unpredictable malperfusion and its mechanism were examined....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2013-05, Vol.95 (5), p.1570-1576
1. Verfasser: Orihashi, Kazumasa, MD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Despite a reduced incidence of false lumen perfusion with preferential use of axillary arterial perfusion in acute type A aortic dissection, malperfusion remains a major cause of operative mortality and sequelae. The incidence of unpredictable malperfusion and its mechanism were examined. Methods We examined the 59 consecutive cases of type A aortic dissection treated surgically, including 17 cases (28.8%) with preoperative malperfusion. Whereas femoral arterial perfusion was used in 7 cases with profound shock, axillary arterial perfusion was employed in the remaining 52 cases. Organ perfusion was assessed with various modalities including transesophageal echocardiography, orbital Doppler, and near-infrared spectroscopy. Results Although false lumen perfusion was not encountered, persistent or new malperfusion was detected in 5 cases (8.5%) with unrestored true lumen. Malperfusion remained in 3 cases. Of these, bilateral axillary arterial perfusion in 1 case and selective perfusion through the femoral artery in 1 case were effective; however, additional ascending aortic cannulation in 1 case was unsuccessful. In the remaining 2 cases, unilateral axillary arterial perfusion led to reduced oxygen saturation in the contralateral frontal lobe, which was restored by bilateral axillary arterial perfusion probably due to augmented collateral circulation. Subclavian steal due to occluded innominate artery was detected in 1 of them. Immediate decision making based on real-time information was beneficial. Conclusions Despite preferential axillary arterial perfusion, new or persistent malperfusion occurred in 5 cases (8.5%). There is no perfect perfusion route but real-time assessment and individualized navigation may be beneficial in further improving the outcomes.
ISSN:0003-4975
1552-6259
DOI:10.1016/j.athoracsur.2013.02.025