Factors affecting the stability of reverse shoulder arthroplasty: a biomechanical study

Background Despite the success of reverse shoulder arthroplasty (RSA) in treating patients with painful pseudoparalytic shoulders, instability is a common complication and currently the factors affecting stability are not well understood. The objective of this study was to investigate a number of fa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of shoulder and elbow surgery 2013-04, Vol.22 (4), p.439-444
Hauptverfasser: Clouthier, Allison L., MASc, Hetzler, Markus A., BASc, Fedorak, Graham, MD, Bryant, J. Tim, PhD, Deluzio, Kevin J., PhD, Bicknell, Ryan T., MD, MSc, FRCSC
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Despite the success of reverse shoulder arthroplasty (RSA) in treating patients with painful pseudoparalytic shoulders, instability is a common complication and currently the factors affecting stability are not well understood. The objective of this study was to investigate a number of factors as well as the interactions between factors to determine how they affect the stability of the prosthesis. These factors included: active arm posture (abduction and abduction plane angles), loading direction, glenosphere diameter and eccentricity, and humeral socket constraint. Methods Force required to dislocate the joint, determined using a biomechanical shoulder simulator, was used as a measure of stability. A factorial design experiment was implemented to examine the factors and interactions. Results Actively increasing the abduction angle by 15° leads to a 30% increase in stability and use of an inferior-offset rather than a centered glenosphere improved stability by 17%. Use of a more constrained humeral socket also increased stability; but the effect was dependent on loading direction, with a 88% improvement for superior loading, 66% for posterior, 36% for anterior, and no change for inferior loading. Abduction plane angle and glenosphere diameter had no effect on stability. Conclusion Increased glenohumeral abduction and the use of an inferior-offset glenosphere were found to increase the stability of RSA. Additionally, use of a more constrained humeral socket increased stability for anterior, posterior, and superior loading. These identified factor effects have the potential to decrease the risk of dislocation following RSA.
ISSN:1058-2746
1532-6500
DOI:10.1016/j.jse.2012.05.032