Pulmonary Arteriovenous Malformation Embolization: How We Do It
We report our experience with an embolization technique that allows safe, controllable exclusion of pulmonary arteriovenous malformations using detachable coils, a single venous access site, coaxial catheter guidance, and 1 or 2 microcatheters. This technique is particularly useful when treating cen...
Gespeichert in:
Veröffentlicht in: | Techniques in vascular and interventional radiology 2013-03, Vol.16 (1), p.39-44 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report our experience with an embolization technique that allows safe, controllable exclusion of pulmonary arteriovenous malformations using detachable coils, a single venous access site, coaxial catheter guidance, and 1 or 2 microcatheters. This technique is particularly useful when treating central lesions with a short feeding artery and when high flow increases the risk of coil migration and nontarget embolization. It affords precise placement and repositioning of coils prior to detachment. The technique facilitates safe and successful endovascular closure of these challenging lesions. |
---|---|
ISSN: | 1089-2516 1557-9808 |
DOI: | 10.1053/j.tvir.2013.01.005 |