Reverse-flow strategy in biofilters treating CS2 emissions
The bacteriostatic properties of carbon disulphide (CS 2 ) hamper its biodegradation in conventional biofilters. The response of four biofilters operating in downflow mode and reverse-flow mode was compared in a laboratory-scale plant treating CS 2 under sudden short-term changes in operating condit...
Gespeichert in:
Veröffentlicht in: | Bioprocess and biosystems engineering 2013-04, Vol.36 (4), p.389-397 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The bacteriostatic properties of carbon disulphide (CS
2
) hamper its biodegradation in conventional biofilters. The response of four biofilters operating in downflow mode and reverse-flow mode was compared in a laboratory-scale plant treating CS
2
under sudden short-term changes in operating conditions. A process shutdown for 24 h, an inlet concentration increase and an interruption of the inlet air humidification for 48 h at an empty bed residence time (EBRT) of 240 s did not impact significantly on biodegradation performance, regardless of flow mode. Nevertheless, a reduction in the EBRT to 60 s resulted in a significant decrease in removal efficiency in all the biofilters. The CS
2
degradation profile showed that the reverse-flow mode strategy rendered a more homogenous distribution of biomass along the bed height. The benefits of the reverse-flow mode were demonstrated even when the unidirectional flow mode was re-established. |
---|---|
ISSN: | 1615-7591 1615-7605 |
DOI: | 10.1007/s00449-012-0795-0 |