Abstract Background Locking-plate osteosynthesis is a well-established treatment option for proximal humerus fractures. The standard approach is delta-pectoral, but few data using the minimally invasive antero-lateral delta-split approach exist. The aim of the study was to prospectively evaluate sho...
Gespeichert in:
Veröffentlicht in: | Injury 2013-04, Vol.44 (4), p.456-460 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract Background Locking-plate osteosynthesis is a well-established treatment option for proximal humerus fractures. The standard approach is delta-pectoral, but few data using the minimally invasive antero-lateral delta-split approach exist. The aim of the study was to prospectively evaluate shoulder function and radiological outcome after a minimally invasive antero-lateral delta-split approach. Materials and methods From December 2007 to October 2010, 124 patients with proximal humerus fractures were treated with locking-plate osteosynthesis using a minimally invasive antero-lateral delta-split approach. Complete prospective clinical and radiographic data were available for 97 patients for a minimum 1-year follow-up period. Results After a follow-up period of 18 ± 6 months, the patients achieved a mean absolute Constant score of the injured shoulder of 75 ± 11, equalling 91% of the contralateral shoulder Constant score ( p < 0.01). Implant-related complications (e.g., screw perforation) were observed in seven patients (7.2%), and avascular necrosis occurred in eight patients (8.2%). Damage to the ventral branch of the axillary nerve was recorded in four cases (4%) without any clinical consequences. The mean delay between trauma and surgery was 0.5 days. The procedures were performed by a total of 16 surgeons who required an average of 73 ± 27 min of OR time and 108 ± 121 s of fluoroscopy time. Conclusions Minimally invasive osteosynthesis using angle-stable implants for proximal humerus fractures demonstrated good functional results. Compared to the literature, this minimally invasive procedure resulted in a shorter operation time and may have reduced the avascular necrosis rate. Level of evidence Level IIb, monocentric prospective cohort study. |
---|---|
ISSN: | 0020-1383 1879-0267 |
DOI: | 10.1016/j.injury.2012.09.010 |