Evaluation of the Storz CMAC®, Glidescope® GVL, AirTraq®, King LTS-D™, and direct laryngoscopy in a simulated difficult airway

Abstract Objective The aim of this study was to compare first-attempt and overall success rates and success rates in relation to placement time among 5 different airway management devices: Storz CMAC, Glidescope GVL, AirTraq, King LTS-D, and direct laryngoscopy (DL). Methods Emergency medical techni...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of emergency medicine 2013-03, Vol.31 (3), p.589-592
Hauptverfasser: Nelson, Jessie G., MD, Wewerka, Sandi S., MPH, EMT-B, Woster, Casey M., MD, Burnett, Aaron M., MD, Salzman, Joshua G., MA, EMT-B, Frascone, Ralph J., MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Objective The aim of this study was to compare first-attempt and overall success rates and success rates in relation to placement time among 5 different airway management devices: Storz CMAC, Glidescope GVL, AirTraq, King LTS-D, and direct laryngoscopy (DL). Methods Emergency medical technician basic (EMT-B), EMT-paramedics (EMT-P), and emergency medicine residents and staff physicians placed each of the 5 devices in a random order into an AirSim (TruCorp, Belfast, UK) part-task training manikin. The difficult airway scenario was created by fixing the manikin head to a stationary object and introducing simulated emesis into the hypopharynx. First-attempt and overall success and success in relation to placement time were compared. Provider feedback about device performance was also evaluated. Results Ninety-four providers (16 EMT-basics, 54 EMT-paramedics, and 24 emergency department doctors of medicine) consented to participation. First-attempt and overall success rates for DL, King LTS-D, GVL, and CMAC were not statistically different. Compared with DL, the AirTraq was 96% less likely to be placed successfully (odds ratio, 0.04; 95% confidence interval [CI], 0.01-0.14). When time was factored into the model, the odds of successful placement of the King LTS-D were higher compared with DL (hazard ratio [HR], 1.80; 95% CI, 1.34-2.42) and lower for GVL (HR, 0.59; 95% CI, 0.44-0.80) and AirTraq (HR, 0.228; 95% CI, 0.16-0.325). Providers ranked the CMAC first in terms of performance and preference for use in their practice setting. Conclusion Overall success rates for DL, King-LTS-D, and both video laryngoscope systems were not different. When time was factored into the model, the King LTS-D was more likely to be placed successfully.
ISSN:0735-6757
1532-8171