On the Robust Control of Buck-Converter DC-Motor Combinations
The concepts of active disturbance rejection control and flatness-based control are used in this paper to regulate the response of a dc-to-dc buck power converter affected by unknown, exogenous, time-varying load current demands. The generalized proportional integral observer is used to estimate and...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power electronics 2013-08, Vol.28 (8), p.3912-3922 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The concepts of active disturbance rejection control and flatness-based control are used in this paper to regulate the response of a dc-to-dc buck power converter affected by unknown, exogenous, time-varying load current demands. The generalized proportional integral observer is used to estimate and cancel the time-varying disturbance signals. A key element in the proposed control for the buck converter-dc motor combination is that even if the control input gain is imprecisely known, the control strategy still provides proper regulation and tracking. The robustness of this method is further extended to the case of a double buck topology driving two different dc motors affected by different load torque disturbances. Simulation results are provided. |
---|---|
ISSN: | 0885-8993 1941-0107 |
DOI: | 10.1109/TPEL.2012.2227806 |