Bail out use of the gore excluder following pulmonary conduit rupture during transcatheter pulmonary valve replacement
This report describes the use of the Gore Excluder self‐expanding stent to successfully exclude a contained right ventricle to pulmonary artery conduit rupture during transcatheter pulmonary valve replacement (tPVR). This stent was designed for percutaneous abdominal aortic aneurysm exclusion; howev...
Gespeichert in:
Veröffentlicht in: | Catheterization and cardiovascular interventions 2013-02, Vol.81 (2), p.331-334 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This report describes the use of the Gore Excluder self‐expanding stent to successfully exclude a contained right ventricle to pulmonary artery conduit rupture during transcatheter pulmonary valve replacement (tPVR). This stent was designed for percutaneous abdominal aortic aneurysm exclusion; however, its use in this setting allowed progression to tPVR following conduit rupture without the need for emergent surgery. © 2012 Wiley Periodicals, Inc. |
---|---|