Which lumen is the source of catheter-related bloodstream infection in patients with multi-lumen central venous catheters?
Purpose Paired blood cultures, drawn from the catheter and a peripheral vein, used for calculation of the differential time to positivity (DTP), have been proposed for the detection of catheter-related bloodstream infections (CRBSIs). The most relevant catheter lumen to be sampled in multi-lumen cen...
Gespeichert in:
Veröffentlicht in: | Infection 2013-02, Vol.41 (1), p.49-52 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
Paired blood cultures, drawn from the catheter and a peripheral vein, used for calculation of the differential time to positivity (DTP), have been proposed for the detection of catheter-related bloodstream infections (CRBSIs). The most relevant catheter lumen to be sampled in multi-lumen central venous catheters (CVCs) has not been recommended.
Methods
Forty-four febrile neutropaenic patients, following haematopoietic stem cell transplantation (HSCT) and with multi-lumen CVCs in place, were investigated using the DTP method of blood samples drawn from every lumen of the CVC and a peripheral vein.
Results
Twelve of 44 patients (27 %) had CRBSIs, as determined by the DTP method. In 10 of 12 (83 %) febrile neutropaenic patients, after HSCT, CRBSIs originated from the CVC lumen used for parenteral nutrition and blood products only. 17 % had CRBSI originating from the other CVC lumen (
p
= 0.039).
Conclusion
In most patients, CRBSIs originated from the CVC lumen used for parenteral nutrition and blood products, indicating that this lumen is the main source of CRBSI. However, since 17 % of patients had CRBSIs originating from another lumen, each lumen of multi-lumen CVCs has to be considered as a potential source of CRBSI and should, ideally, be sampled in order to avoid failure in diagnostic procedures. |
---|---|
ISSN: | 0300-8126 1439-0973 |
DOI: | 10.1007/s15010-012-0391-x |